Our website offers a number of parametric search capabilities, one of which allows you to search specifically for NSN parts. This means you can quickly sort through National Stock Numbers such as 5925001803246 and find parts like part number SM3 5DC1 from quality manufacturers like Eaton Corporation and many others. To begin the purchasing process immediately, submit an RFQ today. Our team of dedicated account managers is standing by and will respond to all inquiries in 15 minutes or less.
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | HERMETICALLY SEALED |
AAQL | Body Style | SINGLE POLE TYPE |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 1.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 4.500 MAXIMUM AT 200 PCT SINGLE LOCATION |
AFJN | Fragility Factor | MODERATELY RUGGED |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 50.0 DC SINGLE LOCATION |
ABXD | Bushing Length | 0.360 INCHES MINIMUM AND 0.380 INCHES MAXIMUM |
MRC | Decoded Requirement | Clear Text Reply |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 500.0 DC SINGLE LOCATION |
CPRJ | Trip Release Method | MAGNETIC SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
ADAT | Body Width | 0.567 INCHES MINIMUM AND 0.629 INCHES MAXIMUM |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 SINGLE LOCATION |
AKPX | Pole Quantity | 1 |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
CPRP | Ultimate Trip Time Per Pole In Seconds | 40.000 NOMINAL SINGLE LOCATION |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRQ | Reset Method | MANUAL |
CPRW | Actuator Function | TRIP-RESET |
ADTV | Case Material | METAL |
CPRX | Actuator Position Designation | AT POLE ONE |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
AJWX | Mounting Surface To Terminal End Distance | 1.524 INCHES MINIMUM AND 1.586 INCHES MAXIMUM |
ADAQ | Body Length | 1.448 INCHES MINIMUM AND 1.510 INCHES MAXIMUM |
CQJX | Nominal Thread Size | 0.375 INCHES |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.870 INCHES MINIMUM AND 0.880 INCHES MAXIMUM |
TTQY | Terminal Type And Quantity | 2 WIRE HOOK |
CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES DC SINGLE LOCATION |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
THSD | Thread Series Designator | UNEF |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
CMLP | Thread Quantity Per Inch | 32 |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |