Mfg Part Number: 8500-005-1
Alternate P/N: 85000051
NSN : 5925-01-380-7283
NIIN : 013807283
CAGE Code : 81640
Manufacturer: Eaton Corporation
Item Name : Circuit Breaker Circuit Breaker
FSC : 5925 Circuit Breakers
Our website offers a number of parametric search capabilities, one of which allows you to search specifically for NSN parts. This means you can quickly sort through National Stock Numbers such as 5925013807283 and find parts like part number 8500-005-1 from quality manufacturers like Eaton Corporation and many others. To begin the purchasing process immediately, submit an RFQ today. Our team of dedicated account managers is standing by and will respond to all inquiries in 15 minutes or less.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-380-7283 Item Description: Circuit Breaker | 5925 | 013807283 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
8500-005-1 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
THSD | Thread Series Designator | UNS |
AAQL | Body Style | SINGLE POLE TYPE |
CQXF | Inclosure Protection Type For Which Designed | VIBRATION RESISTANT AND SHOCK RESISTANT AND SAND RESISTANT AND DUSTTIGHT AND CORROSION RESISTANT AND HUMIDITY RESISTANT AND EXPLOSION PROOF |
AFJN | Fragility Factor | MODERATELY RUGGED |
PKWT | Unpackaged Unit Weight | 29.0 GRAMS |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
BBRJ | Special Handling Feature | MAGNETIC |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 120.0 AC ALL LOCATIONS |
ABXD | Bushing Length | 0.359 INCHES NOMINAL |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 800.0 AC ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 2 TAB W/SCREW |
ADAT | Body Width | 0.562 INCHES NOMINAL |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
AKPX | Pole Quantity | 1 |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 145.0 ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPRT | Manual Actuator Type And Quantity | 1 PUSH-PULL |
CPRX | Actuator Position Designation | AT POLE ONE |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
ADTV | Case Material | PLASTIC |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
MRC | Decoded Requirement | Clear Text Reply |
AJWX | Mounting Surface To Terminal End Distance | 1.287 INCHES MINIMUM AND 1.317 INCHES MAXIMUM |
ADAQ | Body Length | 0.750 INCHES NOMINAL |
CQJX | Nominal Thread Size | 0.438 INCHES |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.593 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 1.0 AMPERES AC ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CMLP | Thread Quantity Per Inch | 32 |
CPRW | Actuator Function | TRIP-RESET |