Mfg Part Number: H851-2001-99
Alternate P/N: H851200199
NSN : 5925-01-497-1928
NIIN : 014971928
CAGE Code : 96169
Manufacturer: Electric Boat Corporation
Item Name : Circuit Breaker Circuit Breaker
FSC : 5925 Circuit Breakers
Our website offers a number of parametric search capabilities, one of which allows you to search specifically for NSN parts. This means you can quickly sort through National Stock Numbers such as 5925014971928 and find parts like part number H851-2001-99 from quality manufacturers like Electric Boat Corporation and many others. To begin the purchasing process immediately, submit an RFQ today. Our team of dedicated account managers is standing by and will respond to all inquiries in 15 minutes or less.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-497-1928 Item Description: Circuit Breaker | 5925 | 014971928 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
H851-2001-99 | 5 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.750 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES AC ALL LOCATIONS |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT AND MOISTURE RESISTANT AND SALT WATER RESISTANT |
MRC | Decoded Requirement | Clear Text Reply |
AKPX | Pole Quantity | 3 |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 50.0 AC ALL LOCATIONS |
CQSM | Switch Location And Position Designation | INTERNAL AT POLE ONE |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
AJEC | Boss Height | 0.220 INCHES NOMINAL |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CSSX | Switch Current Rating And Type In Amps | 5.0 AC AND 1.0 DC |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 1000.0 ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 1.026 INCHES NOMINAL |
CPRP | Ultimate Trip Time Per Pole In Seconds | 0.800 MINIMUM ALL LOCATIONS AND 7.000 MAXIMUM ALL LOCATIONS |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
CPRW | Actuator Function | TRIP-RESET |
ADAT | Body Width | 3.108 INCHES NOMINAL |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRX | Actuator Position Designation | AT EACH POLE |
CSWP | Switch Voltage Rating And Type In Volts | 250.0 AC AND 50.0 DC |
ZZZK | Specification/Standard Data | 81349-MIL-C-55629/17 GOVERNMENT SPECIFICATION |
CQJX | Nominal Thread Size | 0.138 INCHES |
ADTV | Case Material | PLASTIC |
AJWX | Mounting Surface To Terminal End Distance | 3.460 INCHES MINIMUM AND 3.580 INCHES MAXIMUM |
ADAQ | Body Length | 5.125 INCHES NOMINAL |
CMLP | Thread Quantity Per Inch | 32 |
AGAV | End Item Identification | WEAPON LAUNCH CONSOLE ASSEMBLY FOR LOSANGELES CLASS SUBMARINE 688 |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 3.480 INCHES MINIMUM AND 3.614 INCHES MAXIMUM |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.996 INCHES MINIMUM AND 1.056 INCHES MAXIMUM |
FEAT | Special Features | CIRCUIT BREAKER HAS THREE POLE, SINGLE THROW NORMALLY OPEN SWITCH CONTACT ARRANGEMENT; MOUNT IN VERTICAL PLANE |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CRTK | Switch Terminal Type | PIN |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.150 MINIMUM AT 200 PCT ALL LOCATIONS AND 1.000 MAXIMUM AT 200 PCT ALL LOCATIONS AND 0.032 MINIMUM AT 400 PCT ALL LOCATIONS AND 0.250 MAXIMUM AT 400 PCT ALL LOCATIONS AND 0.110 MAXIMUM AT 800 PCT ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
THSD | Thread Series Designator | UNC |
TEST | Test Data Document | 81349-MIL-C-55629 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.