Mfg Part Number: 8M552
NSN : 5950-00-260-0505
NIIN : 002600505
CAGE Code : 88431
Manufacturer: General Transformer Co Ltd
Item Name : Transformer Power A Transformer Power A
Our website offers a number of parametric search capabilities, one of which allows you to search specifically for NSN parts. This means you can quickly sort through National Stock Numbers such as 5950002600505 and find parts like part number 8M552 from quality manufacturers like General Transformer Co Ltd and many others. To begin the purchasing process immediately, submit an RFQ today. Our team of dedicated account managers is standing by and will respond to all inquiries in 15 minutes or less.
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 6.063 INCHES NOMINAL |
ADAT | BODY WIDTH | 5.188 INCHES NOMINAL |
ADAU | BODY HEIGHT | 6.500 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY, VARIABLE AUTOTRANSFORMER TYPE SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 24.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
CRMJ | WINDING POWER RATING | 2.7 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
CWJS | WINDING OPERATING VOLTAGE | 11.50 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT AND 22.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT AND 33.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT AND 43.00 AC VOLTS NOMINAL SINGLE COMPONENT SI |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT |
TTQY | TERMINAL TYPE AND QUANTITY | 21 THREADED STUD |