Mfg Part Number: S70-0006-001
Alternate P/N: S700006001
NSN : 5930-00-501-0836
NIIN : 005010836
CAGE Code : 14304
Manufacturer: Harris Llc
Item Name : Switch Thermostatic Switch Thermostatic
FSC : 5930 Switches
Our website offers a number of parametric search capabilities, one of which allows you to search specifically for NSN parts. This means you can quickly sort through National Stock Numbers such as 5930005010836 and find parts like part number S70-0006-001 from quality manufacturers like Harris Llc and many others. To begin the purchasing process immediately, submit an RFQ today. Our team of dedicated account managers is standing by and will respond to all inquiries in 15 minutes or less.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-501-0836 Item Description: Switch Thermostatic | 5930 | 005010836 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | ||||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
S70-0006-001 | E | 1 | C |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | III OVERALL LENGTH | 1.240 INCHES MINIMUM AND 1.260 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 0.627 INCHES MINIMUM AND 0.650 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 0.680 INCHES NOMINAL |
ABPM | BODY DIAMETER | 0.610 INCHES MINIMUM AND 0.630 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.367 INCHES MINIMUM AND 0.390 INCHES MAXIMUM |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.928 INCHES MINIMUM |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
AWTN | OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 500.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | BRACKET |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CSCF | TERMINAL TYPE | TAB, SOLDER LUG |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE AND 1.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE AND 500.0 MILLIAMPERES LAMP LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE AND 2.5 AMPERES INDUCTIVE LOAD SECOND VOLTAGE AND 1.0 AMPERES LAMP LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE AND 2.5 AMPERES INDUCTIVE LOAD THIRD VOLTAGE AND 1.0 AMPERES LAMP LOAD THIRD VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CTYX | CONTACT STIMULUS RATING | 180.00 ACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 190.00 ACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 165.00 DEACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 175.00 DEACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 15.00 DIFFERENTIAL P |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT ALTITUDE THIRD VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SECOND VOLTAGE |
FREQ | FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS |
STYL | III STYLE DESIGNATOR | DISC W/FLANGE |
TEST | TEST DATA DOCUMENT | 81349-MIL-S-24236 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI |