Item Name : Transformer Power Transformer Power
Our website offers a number of parametric search capabilities, one of which allows you to search specifically for NSN parts. This means you can quickly sort through National Stock Numbers such as 5950013401296 and find parts like part number 9100-4176 from quality manufacturers like Keysight Technologies Inc and many others. To begin the purchasing process immediately, submit an RFQ today. Our team of dedicated account managers is standing by and will respond to all inquiries in 15 minutes or less.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-340-1296 Item Description: Transformer Power | 5950 | 013401296 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
9100-4176 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 4.452 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.740 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.228 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 48.0 HERTZ MINIMUM SINGLE COMPONENT AND 66.0 HERTZ MAXIMUM SINGLE COMPONENT |
ADAU | BODY HEIGHT | 4.137 INCHES NOMINAL |
AEHZ | MAXIMUM OPERATING TEMP | 65.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | OPEN |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 4.0 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 15.6 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CRMJ | WINDING POWER RATING | 19.7 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 40.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 100.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY AND 120.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 100.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY AND 120.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 19.70 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
FEAT | SPECIAL FEATURES | A NO. 22 AWG WIRE LEAD IS CONNECTED TO THE BLACK/RED WIRE LEAD OF THE SECOND PRIMARY WINDING |
TTQY | TERMINAL TYPE AND QUANTITY | 17 WIRE LEAD |
ABTD | MOUNTING SLOT WIDTH | 0.236 INCHES NOMINAL SINGLE GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO TERMINAL SINGLE COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 500.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 31.20 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
ADAT | BODY WIDTH | 3.861 INCHES NOMINAL |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 10.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |