Mfg Part Number: 13966
NSN : 5950-01-243-0714
NIIN : 012430714
CAGE Code : 53854
Manufacturer: Magnespec Inc
Item Name : Transformer Power Transformer Power
Our website offers a number of parametric search capabilities, one of which allows you to search specifically for NSN parts. This means you can quickly sort through National Stock Numbers such as 5950012430714 and find parts like part number 13966 from quality manufacturers like Magnespec Inc and many others. To begin the purchasing process immediately, submit an RFQ today. Our team of dedicated account managers is standing by and will respond to all inquiries in 15 minutes or less.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-243-0714 Item Description: Transformer Power | 5950 | 012430714 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
13966 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.100 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.147 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 10.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 2.450 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.020 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.450 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 10.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 320.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 5.9 AMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 6.0 AMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 2.6 WATTS SINGLE COMPONENT 3RD SECONDARY |
CRMJ | WINDING POWER RATING | 50.0 MILLIWATTS SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 70.0 WATTS SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 96.0 WATTS SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 16.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 18.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 8.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 14 PIN |