Mfg Part Number: XLS450
NSN : 6130-01-257-5435
NIIN : 012575435
CAGE Code : 31557
Manufacturer: Natel Engineering Company Inc
Item Name : Power Supply Power Supply
Our website offers a number of parametric search capabilities, one of which allows you to search specifically for NSN parts. This means you can quickly sort through National Stock Numbers such as 6130012575435 and find parts like part number XLS450 from quality manufacturers like Natel Engineering Company Inc and many others. To begin the purchasing process immediately, submit an RFQ today. Our team of dedicated account managers is standing by and will respond to all inquiries in 15 minutes or less.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-257-5435 Item Description: Power Supply | 6130 | 012575435 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Xls450 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 12.300 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.560 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 6.000 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | FUNGUS PROOF AND SHOCK PROOF |
AGAV | END ITEM IDENTIFICATION | TRANS MODULE STA |
AKAE | MAXIMUM OPERATING ALTITUDE RATING | 15000.0 FEET |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 103.5 AC VOLTS MINIMUM SINGLE OPERATING POWER RQMT AND 129.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -12.0 DC VOLTS NOMINAL 4TH POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 28.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 380.0 HERTZ MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 420.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.5 HERTZ MINIMUM 3RD ALTERNATE OPERATING POWER RQMT AND 52.5 HERTZ MAXIMUM 3RD ALTERNATE OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 57.0 HERTZ MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | -10.0/+55.0 DEG CELSIUS |
CBBL | FEATURES PROVIDED | CIRCUIT OVERLOAD PROTECTION DEVICE AND OVER VOLTAGE PROTECTOR AND INPUT TO OUTPUT ISOLATION AND INPUT TO CASE ISOLATION AND OUTPUT TO CASE ISOLATION |
CWGH | OUTPUT CURRENT RATING | 0.1 DC AMPERES NOMINAL 4TH POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 1.6 DC AMPERES NOMINAL 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 1.6 DC AMPERES NOMINAL 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 5.5 DC AMPERES NOMINAL 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 5 SINGLE POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP SINGLE POWER OUTPUT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP SINGLE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 2 SINGLE OPERATING POWER RQMT |
CWKG | VENTILATION DESIGN TYPE | CONVECTION |
CWWY | POWER SUPPLY EFFICIENCY LINE | 60.0 |
NHCF | NUCLEAR HARDNESS CRITICAL FEATURE | HARDENED |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote