Mfg Part Number: 5302
NSN : 5950-00-788-2361
NIIN : 007882361
CAGE Code : 95266
Manufacturer: Oeco Corp
Item Name : Transformer Power Transformer Power
Our website offers a number of parametric search capabilities, one of which allows you to search specifically for NSN parts. This means you can quickly sort through National Stock Numbers such as 5950007882361 and find parts like part number 5302 from quality manufacturers like Oeco Corp and many others. To begin the purchasing process immediately, submit an RFQ today. Our team of dedicated account managers is standing by and will respond to all inquiries in 15 minutes or less.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-788-2361 Item Description: Transformer Power | 5950 | 007882361 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
5302 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
POWER | ADAT | BODY WIDTH3 125 INCHES NOMINAL |
POWER | AEHZ | MAXIMUM OPERATING TEMP105 0 DEG CELSIUS |
POWER | AKNA | INCLOSURE TYPEPARTIALLY INCLOSED DOUBLE SHELL |
POWER | BPLC | WINDING FUNCTION AND QUANTITY2 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |
POWER | TTQY | TERMINAL TYPE AND QUANTITY12 LINE CORD |
POWER | AARG | RELIABILITY INDICATORNOT ESTABLISHED |
POWER | ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2 875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
POWER | ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2 875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
POWER | ACZB | FREQUENCY RATING50 0 HERTZ NOMINAL SINGLE COMPONENT OR 60 0 HERTZ NOMINAL SINGLE COMPONENT |
POWER | ACZC | INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
POWER | ADAQ | BODY LENGTH3 625 INCHES NOMINAL |
POWER | ADAU | BODY HEIGHT3 750 INCHES NOMINAL |
POWER | AKPV | MOUNTING FACILITY QUANTITY4 SINGLE GROUP |
POWER | AXGY | MOUNTING METHODFLANGE SINGLE GROUP AND SLOT SINGLE GROUP |
POWER | CRBZ | WINDING OPERATING CURRENT1 5 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
POWER | CWJS | WINDING OPERATING VOLTAGE115 00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST PRIMARY |