Mfg Part Number: DU 1 4
Alternate P/N: DU14
NSN : 5950-00-518-7522
NIIN : 005187522
CAGE Code : 08779
Manufacturer: Signal Transformer Co Inc
Item Name : Transformer Power Transformer Power
Our website offers a number of parametric search capabilities, one of which allows you to search specifically for NSN parts. This means you can quickly sort through National Stock Numbers such as 5950005187522 and find parts like part number DU 1 4 from quality manufacturers like Signal Transformer Co Inc and many others. To begin the purchasing process immediately, submit an RFQ today. Our team of dedicated account managers is standing by and will respond to all inquiries in 15 minutes or less.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-518-7522 Item Description: TRANSFORMER,POWER | 5950 | 005187522 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
DU-1/4 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABHP | OVERALL LENGTH | 5.312 INCHES MAXIMUM5.312 INCHES MAXIMUM5.312 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 5.250 INCHES MAXIMUM5.250 INCHES MAXIMUM5.250 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 4.250 INCHES MAXIMUM4.250 INCHES MAXIMUM4.250 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.196 INCHES NOMINAL SINGLE GROUP0.196 INCHES NOMINAL SINGLE GROUP0.196 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 500.0 HERTZ MAXIMUM SINGLE COMPONENT500.0 HERTZ MAXIMUM SINGLE COMPONENT500.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 0.250 VOLT-AMPERE SINGLE COMPONENT0.250 VOLT-AMPERE SINGLE COMPONENT0.250 VOLT-AMPERE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | OPENOPENOPEN |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND SLOT SINGLE GROUPSLOT SINGLE GROUPSLOT SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 PRIMARY SINGLE COMPONENT AND 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT2 SECONDARY SINGLE COMPONENT2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 2.2 AMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 104.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 104.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 110.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 110.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 120.00 AC VO |
CWJS | WINDING OPERATING VOLTAGE | 104.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY OR 104.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY OR 110.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY OR 110.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY OR 120.00 A |
TTQY | TERMINAL TYPE AND QUANTITY | 16 THREADED STUD |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote