Mfg Part Number: 2006
NSN : 5950-01-070-6616
NIIN : 010706616
CAGE Code : 23951
Manufacturer: Standard Industries Inc
Item Name : Transformer Power Transformer Power
Our website offers a number of parametric search capabilities, one of which allows you to search specifically for NSN parts. This means you can quickly sort through National Stock Numbers such as 5950010706616 and find parts like part number 2006 from quality manufacturers like Standard Industries Inc and many others. To begin the purchasing process immediately, submit an RFQ today. Our team of dedicated account managers is standing by and will respond to all inquiries in 15 minutes or less.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-070-6616 Item Description: Transformer Power | 5950 | 010706616 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
2006 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
POWER | AARG | RELIABILITY INDICATORNOT ESTABLISHED |
POWER | ABHP | OVERALL LENGTH2 750 INCHES NOMINAL |
POWER | ABKW | OVERALL HEIGHT1 730 INCHES NOMINAL |
POWER | ABMK | OVERALL WIDTH1 510 INCHES NOMINAL |
POWER | ABTD | MOUNTING SLOT WIDTH0 190 INCHES NOMINAL SINGLE GROUP |
POWER | ACZB | FREQUENCY RATING80 0 KILOHERTZ NOMINAL SINGLE COMPONENT |
POWER | ACZC | INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
POWER | ACZX | WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
POWER | AEHZ | MAXIMUM OPERATING TEMP105 0 DEG CELSIUS |
POWER | AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS2 300 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
POWER | AKNA | INCLOSURE TYPEFULLY INCLOSED |
POWER | AKPV | MOUNTING FACILITY QUANTITY2 SINGLE GROUP |
POWER | AXGY | MOUNTING METHODBRACKET SINGLE GROUP AND SLOT SINGLE GROUP |
POWER | BPLC | WINDING FUNCTION AND QUANTITY1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
POWER | CRBZ | WINDING OPERATING CURRENT10 0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
POWER | CWJS | WINDING OPERATING VOLTAGE1 20 AC KILOVOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
POWER | TTQY | TERMINAL TYPE AND QUANTITY10 WIRE LEAD |