Mfg Part Number: 6E350CT
NSN : 5950-01-223-4874
NIIN : 012234874
CAGE Code : 15755
Manufacturer: Sure Power Inc
Item Name : Transformer Power Transformer Power
Our website offers a number of parametric search capabilities, one of which allows you to search specifically for NSN parts. This means you can quickly sort through National Stock Numbers such as 5950012234874 and find parts like part number 6E350CT from quality manufacturers like Sure Power Inc and many others. To begin the purchasing process immediately, submit an RFQ today. Our team of dedicated account managers is standing by and will respond to all inquiries in 15 minutes or less.
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 1.345 INCHES MINIMUM AND 1.405 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.925 INCHES MINIMUM AND 0.955 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.985 INCHES MINIMUM AND 1.015 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 0.865 INCHES MINIMUM AND 0.895 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.235 INCHES MINIMUM AND 1.265 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.111 INCHES MINIMUM AND 0.121 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 170.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 350.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 5 TURRET |